Facets (new session)
Description
Metadata
Settings
Rule:
ActivityStreamsMap
asEquivalent
b3s
b3sifp
facets
http://www.w3.org/2002/07/owl#
ldp
oplweb
skos-trans
urn:det:rdf:label
virtrdf-label
virtrdf-url
None
Inverse Functional Properties:
Disabled (fastest)
Apply to subjects only
Apply to objects only
Apply to both subjects and objects
"Same As":
Disabled (fastest)
Apply to subjects only
Apply to objects only
Apply to both subjects and objects (recommended)
Apply to subjects, objects and predicates (not recommended on big datasets)
Apply to predicates only (special use cases only)
About:
TR6715-BC-BC01
Goto
Sponge
NotDistinct
Permalink
An Entity of Type :
http://data.europa.eu/949/Track
, within Data Space :
prod.virtuoso.ecdp.tech.ec.europa.eu
associated with source
document(s)
Type:
Track
New Facet based on Instances of this Class
Attributes
Values
rdf:type
Track
rdfs:label
TR6715-BC-BC01
Canonical URI
http://data.europa.eu/949/functionalInfrastructure/tracks/C237_IT12852_TR6715-BC-BC01_IT12851
Hash source
C237_IT12852_IT12851/None_None/TR6715-BC-BC01/None_None
Use of magnetic brakes
not allowed
Use of eddy current brakes
not allowed
Existence of train...iant with the TSI
0
(
xsd:boolean
)
Train detection system
wheel detector
Trans-European Net...tform, of siding)
Off TEN
Temperature range (maximum)
40
(
xsd:integer
)
Temperature range (minimum)
-25
(
xsd:integer
)
Temperature range
T1 (-25 to +40)
TSI compliance of ...hes and crossings
1
(
xsd:boolean
)
Has abstraction
TR6715-BC-BC01
Normal running direction
B
Identification of track
TR6715-BC-BC01
Existence of severe climatic conditions
0
(
xsd:boolean
)
Rail inclination
1/20
Belonging to a quieter route
0
(
xsd:boolean
)
Standard combined ...r for swap bodies
C 349
C 30
Standard combined ...for semi-trailers
P 349
P 30
Nominal track gauge
1435
Minimum wheel diam... obtuse crossings
330
(
xsd:integer
)
Minimum radius of horizontal curve
384
(
xsd:integer
)
Maximum permitted speed
95
(
xsd:integer
)
Maximum braking distance requested
1200
(
xsd:integer
)
Existence of level crossings
0
(
xsd:boolean
)
Other radio system...o Legacy Systems)
GSM-P
Existence of track...x detector (HABD)
0
(
xsd:boolean
)
GSM-R version
Baseline 1
Optional GSM-R functions
General data applications (*7)
Network selection automatic (*1)
Text message service used (SMS) (*4)
Automatically forward of incoming call if no reply (*5)
Automatically forward of incoming call if not reachable (*5)
Public emergency (112) available (*2)
Gradient profile
+16.9(300.170),+0.0(300.314),+18.6(300.715),+0.0(301.217),+19.9(301.540),+0.0(301.741),-9.0(301.840),-12.5(302.160),+0.0(302.757),+8.6(302.833),+0.0(303.073),-21.0(303.174),+0.0(303.732),+9.0(304.291),+0.0(304.829)
Use of flange lubrication forbidden
0
(
xsd:boolean
)
European Train Con...stem (ETCS) level
N
Contact line system
Not electrified
Cant deficiency
275
(
xsd:integer
)
Not provided
Maximum train deceleration
Category of line
Part of a Railway Freight Corridor
Existence of rules and restrictions of a strictly local nature
Documents regarding the rules or restrictions of a strictly local nature available by the IM
Steady red lights required
TEN geographic information system identity (GIS ID)
Load Capability
Existence and TSI ...tted by a vehicle
TSI compliant
Existence and TSI ...rrent of vehicles
TSI compliant
Gauging
G1
GI2
No GSMR coverage
1
(
xsd:boolean
)
Availability by th...ional information
1
(
xsd:boolean
)
Maximum altitude
+25
Train protection legacy system
RSDD/SCMT
Not applicable
Permitted contact strip material
System separation
Phase separation
Minimum contact wire height
Maximum contact wire height
ETCS M_version
ETCS system compatibility
Contact force permitted
Automatic dropping device required
Acceleration allowed near level crossing
ETCS level for degraded situation
ETCS infill installed line-side
ETCS infill necessary for line access
ETCS national packet 44 application implemented
Number of active GSM-R mobiles (EDOR) or simultaneous communication session on-board for ETCS Level 2 (or level 3) needed to perform radio block centre handovers without having an operational disruption
Existence of operating restrictions or conditions
http://data.europa.eu/949/pantographHead
Requirements for number of raised pantographs and spacing between them, at the given speed
EI declaration of demonstration (as defined Recommendation 2014/881/EU) for track relating to compliance with the requirements from TSIs applicable to energy subsystem
EI declaration of demonstration (as defined Commission 2014/881/EU) for track relating to compliance with the requirements from TSIs applicable to infrastructure subsystem
Distance between signboard and phase separation ending
Existence of ballast
Other train protection, control and warning systems for degraded situation
Information on phase separation
Existence of switch over between different protection, control and warning systems while running
Existence of switch over between different radio systems
Information on system separation
Train integrity confirmation from on-board (not from driver) necessary for line access
EC declaration of verification for track relating to compliance with the requirements from TSIs applicable to energy subsystem
EC declaration of verification for track relating to compliance with the requirements from TSIs applicable to infrastructure subsystem
Document with the conditions for the use of eddy current brakes
Railway location of particular points requiring specific checks
Document with the transversal section of the particular points requiring specific checks
GPRS for ETCS
Area of implementation of GPRS
Compliance of structures with the High Speed Load Model (HSLM)
Generation of trackside HABD
Identification of trackside HABD
Railway location of trackside HABD
Trackside HABD TSI compliant
Document with the conditions for the use of magnetic brakes
◂◂ First
◂ Prev
Next ▸
Last ▸▸
Page 1 of 2
Go
Faceted Search & Find service v1.17_git142 as of May 17 2024
Alternative Linked Data Documents:
ODE
Content Formats:
RDF
ODATA
Microdata
About
OpenLink Virtuoso
version 08.03.3331 as of May 21 2024, on Linux (x86_64-ubuntu_focal-linux-gnu-glibc2.31), Single-Server Edition (31 GB total memory, 19 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software