(Sponging disallowed)
Facets (new session)
Description
Metadata
Settings
Rule:
ActivityStreamsMap
asEquivalent
b3s
b3sifp
facets
http://www.w3.org/2002/07/owl#
ldp
oplweb
skos-trans
urn:det:rdf:label
virtrdf-label
virtrdf-url
None
Inverse Functional Properties:
Disabled (fastest)
Apply to subjects only
Apply to objects only
Apply to both subjects and objects
"Same As":
Disabled (fastest)
Apply to subjects only
Apply to objects only
Apply to both subjects and objects (recommended)
Apply to subjects, objects and predicates (not recommended on big datasets)
Apply to predicates only (special use cases only)
About:
Voie 1
Goto
Sponge
NotDistinct
Permalink
An Entity of Type :
http://data.europa.eu/949/Track
, within Data Space :
prod.virtuoso.ecdp.tech.ec.europa.eu
associated with source
document(s)
Type:
Track
New Facet based on Instances of this Class
Attributes
Values
rdf:type
Track
rdfs:label
Voie 1
Validity end date
2382-01-01
(
xsd:date
)
Validity start date
2003-07-23
(
xsd:date
)
Canonical URI
http://data.europa.eu/949/functionalInfrastructure/tracks/005000-1_FR0000002653_Voie%201_FR0000000461
Hash source
005000-1_FR0000002653_FR0000000461/2003-07-23_2382-01-01/Voie 1/2003-07-23_2382-01-01
Track raised panto...istance and speed
3 8 320
Permitted contact strip material
plain carbon
impregnated carbon (% of metallic content)
Track load capability
D4 000
Use of magnetic brakes
allowed under conditions only for emergency brake
Use of eddy current brakes
allowed under conditions
Existence of train...iant with the TSI
0
(
xsd:boolean
)
Train detection system
Wheeldetector
trackcircuit
loop
Trans-European Net...tform, of siding)
Part of the TEN-T Core Freight Network
Temperature range (maximum)
40
(
xsd:integer
)
Temperature range (minimum)
-25
(
xsd:integer
)
Temperature range
T1 (-25 to +40)
System separation
0
(
xsd:boolean
)
TSI compliance of ...hes and crossings
1
(
xsd:boolean
)
Has abstraction
Voie 1
Normal running direction
B
Identification of track
Voie 1
Existence of severe climatic conditions
0
(
xsd:boolean
)
Rail inclination
1/20
Belonging to a quieter route
0
(
xsd:boolean
)
Phase separation
0
(
xsd:boolean
)
Accepted TSI compliant pantograph heads
1600 mm (EP)
Accepted other pantograph heads
1450 mm
1600 mm (GB,CTRL)
Nominal track gauge
1435
Minimum contact wire height
5.000000
(
xsd:double
)
Minimum wheel diam... obtuse crossings
330
(
xsd:integer
)
Minimum radius of horizontal curve
6250
(
xsd:integer
)
Maximum contact wire height
5.160000
(
xsd:double
)
Maximum train deceleration
2.000000
(
xsd:double
)
Maximum permitted speed
320
(
xsd:integer
)
Maximum braking distance requested
0
(
xsd:integer
)
Category of line
P1
Existence of level crossings
1
(
xsd:boolean
)
Other radio system...o Legacy Systems)
none
Existence of track...x detector (HABD)
1
(
xsd:boolean
)
GSM-R version
previous version to Baseline 0
Optional GSM-R functions
Network selection manual (*1)
Display at the controller terminal of the location of the mobile initiating a REC (Railway Emergency Call) (*8)
Gradient profile
+03.0(+282.660),+03.0(+284.542),+03.0(+287.896),+04.5(+286.254),+05.0,+10.0(+291.436),+22.0(+289.947),+23.0(+295.364),+25.5(+286.946),-02.5(+288.699),-03.0(+293.238),-08.5(+285.658),-16.5(+297.611),-20.5(+294.193)
Use of flange lubrication forbidden
0
(
xsd:boolean
)
European Train Con...stem (ETCS) level
ETCS2
ETCS M_version
1.0
Contact line system
ElectrifiedOCL
ETCS system compatibility
ESC-FR-27-LGVEE
Contact force permitted
118.128
Automatic dropping device required
1
(
xsd:boolean
)
Acceleration allowed near level crossing
PNacc.xlsx
Not provided
Cant deficiency
Existence and TSI ...tted by a vehicle
TSI compliant
Existence and TSI ...rrent of vehicles
TSI compliant
ETCS level for degraded situation
1
ETCS national pack...ation implemented
1
(
xsd:boolean
)
Gauging
GC
GI2
FR-3.3
Number of active G...tional disruption
2
No GSMR coverage
0
(
xsd:boolean
)
Availability by th...ional information
1
(
xsd:boolean
)
Existence of opera...ons or conditions
1
(
xsd:boolean
)
Maximum altitude
+0244
Train protection legacy system
KVB
TVM 430
Not applicable
Standard combined transport profile number for swap bodies
Standard combined transport profile number for semi-trailers
Part of a Railway Freight Corridor
ETCS infill installed line-side
ETCS infill necessary for line access
EI declaration of demonstration (as defined Recommendation 2014/881/EU) for track relating to compliance with the requirements from TSIs applicable to energy subsystem
EI declaration of demonstration (as defined Commission 2014/881/EU) for track relating to compliance with the requirements from TSIs applicable to infrastructure subsystem
Distance between signboard and phase separation ending
Other train protection, control and warning systems for degraded situation
Information on phase separation
Existence of switch over between different radio systems
Information on system separation
Train integrity confirmation from on-board (not from driver) necessary for line access
EC declaration of verification for track relating to compliance with the requirements from TSIs applicable to energy subsystem
Railway location of particular points requiring specific checks
Document with the transversal section of the particular points requiring specific checks
Area of implementation of GPRS
Generation of trackside HABD
Identification of trackside HABD
Railway location of trackside HABD
Existence of rules and restrictions of a strictly local nature
Documents regarding the rules or restrictions of a strictly local nature available by the IM
Details on GSM-R roaming to public networks
Railway location of structures requiring specific checks
TEN geographic information system identity (GIS ID)
Existence of ballast
1
(
xsd:boolean
)
Existence of switc...ems while running
0
(
xsd:boolean
)
EC declaration of ...nalling subsystem
FR/41228073700310/2013/000001
EC declaration of ...ructure subsystem
FR/41228073700310/2008/000001
◂◂ First
◂ Prev
Next ▸
Last ▸▸
Page 1 of 2
Go
Faceted Search & Find service v1.17_git142 as of May 17 2024
Alternative Linked Data Documents:
ODE
Content Formats:
RDF
ODATA
Microdata
About
OpenLink Virtuoso
version 08.03.3331 as of May 21 2024, on Linux (x86_64-ubuntu_focal-linux-gnu-glibc2.31), Single-Server Edition (31 GB total memory, 28 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software